1. Basic Information
| Name: | IRS1_HUMAN |
| Accession#: | P35568 |
| Description: | Insulin receptor substrate 1 |
| AA Number: | 1242 |
| Sequence: |
1 51 101 151 201 251 301 351 401 451 501 551 601 651 701 751 801 851 901 951 1001 1051 1101 1151 1201
|
|
MASPPESDGF SDVRKVGYLR KPKSMHKRFF VLRAASEAGG PARLEYYENE KKWRHKSSAP KRSIPLESCF NINKRADSKN KHLVALYTRD EHFAIAADSE AEQDSWYQAL LQLHNRAKGH HDGAAALGAG GGGGSCSGSS GLGEAGEDLS YGDVPPGPAF KEVWQVILKP KGLGQTKNLI GIYRLCLTSK TISFVKLNSE AAAVVLQLMN IRRCGHSENF FFIEVGRSAV TGPGEFWMQV DDSVVAQNMH ETILEAMRAM SDEFRPRSKS QSSSNCSNPI SVPLRRHHLN NPPPSQVGLT RRSRTESITA TSPASMVGGK PGSFRVRASS DGEGTMSRPA SVDGSPVSPS TNRTHAHRHR GSARLHPPLN HSRSIPMPAS RCSPSATSPV SLSSSSTSGH GSTSDCLFPR RSSASVSGSP SDGGFISSDE YGSSPCDFRS SFRSVTPDSL GHTPPARGEE ELSNYICMGG KGPSTLTAPN GHYILSRGGN GHRCTPGTGL GTSPALAGDE AASAADLDNR FRKRTHSAGT SPTITHQKTP SQSSVASIEE YTEMMPAYPP GGGSGGRLPG HRHSAFVPTR SYPEEGLEMH PLERRGGHHR PDSSTLHTDD GYMPMSPGVA PVPSGRKGSG DYMPMSPKSV SAPQQIINPI RRHPQRVDPN GYMMMSPSGG CSPDIGGGPS SSSSSSNAVP SGTSYGKLWT NGVGGHHSHV LPHPKPPVES SGGKLLPCTG DYMNMSPVGD SNTSSPSDCY YGPEDPQHKP VLSYYSLPRS FKHTQRPGEP EEGARHQHLR LSTSSGRLLY AATADDSSSS TSSDSLGGGY CGARLEPSLP HPHHQVLQPH LPRKVDTAAQ TNSRLARPTR LSLGDPKAST LPRAREQQQQ QQPLLHPPEP KSPGEYVNIE FGSDQSGYLS GPVAFHSSPS VRCPSQLQPA PREEETGTEE YMKMDLGPGR RAAWQESTGV EMGRLGPAPP GAASICRPTR AVPSSRGDYM TMQMSCPRQS YVDTSPAAPV SYADMRTGIA AEEVSLPRAT MAAASSSSAA SASPTGPQGA AELAAHSSLL GGPQGPGGMS AFTRVNLSPN RNQSAKVIRA DPQGCRRRHS SETFSSTPSA TRVGNTVPFG AGAAVGGGGG SSSSSEDVKR HSSASFENVW LRPGELGGAP KEPAKLCGAA GGLENGLNYI DLDLVKDFKQ CPQECTPEPQ PPPPPPPHQP LGSGESSSTR RSSEDLSAYA SISFQKQPED RQ |
|
*Highlighted peptides (with yellow background) have developed assays.
*Green background amino acids are PTMs.
2. Protein Separation
Sample Preparation: Cells from Melanoma cancer cell lines were lysed in 8M urea/ 100mM ammonium bicarbonate buffer on ice. The equivalent of 200,000 cells were loaded onto a SDS gel. The protein of interest was excised and ingel digestion with trypsin was performed after reduction and alkylation with TCEP and IAA. 1/6 of the resulting digest was then analyzed on a Thermo Scientific TSQ mass spectrometer.
3. LC-MS/MS Data
HTQRPGEPEEGAR
No LC-MS/MS for this peptide.
HSSETFSSTPSATR
No LC-MS/MS for this peptide.
4. LC-MRM Screening
Peptides screening: Peptides and transitions for analysis were selected using a predictive peptide program. The results were screened for those with the highest specificity and the most intense transitions.